Tecnología Médica
Tecnología Médica
El aprendizaje profundo (Deep learning) acelera la búsqueda de nuevos andamios antibióticos
17/11/2025 -
El trabajo presenta un avance en el uso de modelos de aprendizaje profundo (deep learning) para acelerar la identificación de nuevos andamios químicos con...
Hintermann Series H3 Total Ankle Replacement Has a Higher-Than-Expected Risk of Device Failure: FDA Safety Communication
14/11/2025 -
Learn more about recommendations for patients who are considering a Hintermann Series H3 TAR system or who have one; recommendations for health care providers.
The effect of using the hip exoskeleton assistive (HEXA) robot compared to conventional physiotherapy on clinical functional outcomes in stroke patients with hemiplegia: a pilot randomized controlled trial
23/10/2025 -
Trial design
This study is a pilot randomized clinical trial aimed to investigate the effect of using Hip Exoskeleton Assistive (HEXA) robot compared to conventional physiotherapy on the...
Comparing scissors and scalpels to a novel surgical instrument: a biomechanical sectioning study
23/10/2025 -
Background
This study introduces a novel surgical instrument to reduce iatrogenic nerve injuries during procedures such as carpal tunnel and ulnar nerve decompression surgery. These...
ANMAT prohíbe dos productos médicos comercializados como Placas de osteosíntesis y Puntas de Shaver
03/10/2025 -
ANMAT informa que, mediante la Disposición 6670/25, se ha resuelto prohibir el uso, comercialización y distribución en todo el...
Influence of crouch angle on lower-extremity kinetic gait profile and walk distance in children with cerebral palsy: a cross-sectional study
23/09/2025 -
Background
Gait kinetics explains dynamics of gait deviations, which inform surgical and non-surgical clinical-decision-making to enhance walking performance of children with cerebral...
Identification of stiff-knee gait in stroke survivors
23/09/2025 -
Background
Stiff-knee gait is a common movement disorder in individuals with stroke; however, standardized criteria for its identification remain lacking. This study aimed to examine...
Low-cost single foot operated mechanical suction machine for rural health centers and hospitals
23/09/2025 -
Introduction
Healthcare practitioners in low and middle-income countries encounter numerous challenges, including insufficient staffing, an unreliable electrical infrastructure, and...
A comparative study of robot-assisted navigation versus C-arm fluoroscopy in percutaneous pedicle screw fixation for the treatment of thoracolumbar fractures
01/09/2025 -
To evaluate the clinical efficacy of ZhuZheng robot-assisted versus C-arm fluoroscopy-guided percutaneous pedicle screw fixation (PPSF) in the treatment of thoracolumbar burst fractures. A...
Fabrication and characterizations of 3D printed GelMA-Gel/bioactive glass scaffolds containing cerium for bone damage repair
01/09/2025 -
Gelatin methacryloyl (GelMA) and bioactive glasses (BGs) have attracted considerable scientific interest as scaffold materialsin bone tissue engineering, particularly for their structural...
CONTRATACIÓN DIRECTA 184/2025
28/08/2025 -
CELDA DE OXIGENO PARA MESA DE ANESTESIA
Distal locking mechanism influences surgical and radiological outcomes in proximal femoral nailing using distal wedge versus distal screw designs
07/08/2025 -
This study aims to evaluate the radiological outcomes of two proximal femoral nails that share similar proximal geometry and sizes, but differ in their distal locking mechanisms. This retrospective...
Sono-activable and biocatalytic 3D-printed scaffolds for intelligently sequential therapies in osteosarcoma eradication and defect regeneration
06/08/2025 -
To mitigate the necessity for multiple invasive procedures in treating malignant osteosarcoma, an innovative therapeutic approach is imperative to achieve controllable tumor-killing effects and...
Brain implantation of soft bioelectronics via embryonic development
30/06/2025 -
Developing bioelectronics capable of stably tracking brain-wide, single-cell, millisecond-resolved neural activity in the developing brain is critical for advancing neuroscience and understanding...
Comparison of Artificial Vertebral Body Analogs to Evaluate Initial Stability of Cervical Disc Replacements
30/06/2025 -
Recent studies have raised concerns regarding migration of cervical disc replacements as a significant clinical complication associated with failure. To date, no laboratory models have addressed...
CONTRATACIÓN DIRECTA 667/2025
30/06/2025 -
ADQUISICIÓN CLAVO PTE: AZAGRA, PABLO
ANMAT advierte sobre placas para osteosíntesis SM Salud falsificadas
26/06/2025 -
A través de una fiscalización de rutina en una empresa distribuidora de productos médicos ubicada en la provincia de Misiones, el Departamento de Control de Mercado de...
CONTRATACIÓN DIRECTA 586/2025
17/06/2025 -
ADQUISICIÓN PROTESIS RODILLA PTE: CORREA, ARMANDO
The Use of Shape Memory Alloys in Cages for Cervical Spinal Surgery
10/06/2025 -
CONCLUSIONS: We feel confident about having developed an alternative cage for ACDF that can potentially reduce peri- and postoperative morbidity and provide long-term stability by reducing bone...
3D printing individualized augments prosthesis and acetabular implant for the treatment of Crowe type III developmental dysplasia of the hip
10/06/2025 -
In patients with Crowe III developmental dysplasia of the hip (DDH), surgery presents challenges such as severe bone defects and inadequate acetabular cup coverage. This study compares the...
Patella Tracker
10/06/2025 -
Disclosed herein are a surgical system for patella tracking and a method for selecting and aligning knee implants utilizing the same. The surgical system may include first and second trackers and...
Mapa TecMed